Skip to main content

How To...


Program Vista 20P - Cheat Sheet

Ademco / Honeywell Vista 20-PProgrammingthe 
Base programming with or without monitoring
Enter ProgrammingInstaller Code + 8 + 00 (default 4112)
Reset / Initialize*97  *96
*20 Installer Codeenter company installer code
*56Zone ProgrammingSee Manual for Zone Programming Page 19
*190To Enable KP Address 171,0   1st digit = Partition, See manual for audio opt
*191-196 For KP address 18-23Same as above
*21Quick Arm Enable1,0
*33Alarm (Bell) Timeout1
*34Exit Delay60
*35Entry Delay30
*37Audible Exit Warning1,1
*39Power up previous state1
*77DST Month Start / End3,11
*78DST Weekend Start / End2,1
*84Auto Stay Arm Disable0
*86Alarm Cancel Display0
*88Program Lockout Mode0
*91Option Selection8,1
*92Phone Line Monitoring0,0
*189AUI Enable1,1,1,1
*197Exit Time Display1
*199ECP Fail Display0
If Monitored 
*43Primary Account NumberLast four digits only
*44Second Account NumberEnter 2nd ACCT # if available
*48Report Format7,7
*50Burglar Dialer Delay0
*60Trouble Report Code10
*61Bypass Report Code10
*63Low Batt Report Code10
*64Test Report Code10
*67RF Trans Low Batt Report Code10
*68Cancel Report Code10
Continue If Monitored 
*70Alarm Restore Code1
*71Trouble Restore Report Code10
*74Low Batt Restore Report Code10
*75RF Low Batt Restore Report Code10
*76Test Restore Report Code10
*93Reports in Armed Period2
If Monitored by Phone 
*41Primary Phone NumberUse Primary 800 monitoring center phone #
*42Second Phone NumberUse 2nd monitoring phone number #
*92Phone Line MonitoringResidential  1,1 / Commercial  1,2 / If Radio Only 0,0
*94Download Informationphone number for downloader (Add 1 for long distance)
*95Ring Count#15
If Using Radio 
*29Enable IP/GSM1,*,*
*54Dynamic Signaling Delay0
*55Dynamic Signaling Priority1
*91Option Selection8,2
Residential Only 
*21Quick Arm Enable1,0
*23Quick (Forced) Bypass1,0
Commercial (If Monitored) 
*62AC Restore Report Code10
*73AC Restore Report Code10
IF YOU WISH TO USE FUNCTION BUTTONS - No response unless monitored
*56Zone ProgrammingProgram Zone 95 as type 09,  Zone 96 as Type 08, Zone 99 as Type 06 for commercial (silent response) or 07 for residential (sirens will go off within system)
*57Assign KP Function ButtonsA - Zone 95 (Fire), B - Zone 99 (Police), C - Zone 96 (Medical)
Exit Programming 
*99Exit Programming, Allowing re-entry with installer code
Set Clock - Enter Installer Code + #63 + * to move forward, # to move back, 1-pm, 2-pm (always 2 digits)
Change Master User Code -  "Current Code" + 8,0,2  + "New code" + "New Code"