Ademco / Honeywell Vista 20-PProgrammingthe |
Base programming with or without monitoring |
Enter Programming | Installer Code + 8 + 00 (default 4112) |
Reset / Initialize | *97 *96 |
*20 | Installer Code | enter company installer code |
*56 | Zone Programming | See Manual for Zone Programming Page 19 |
*190 | To Enable KP Address 17 | 1,0 1st digit = Partition, See manual for audio opt |
*191-196 For KP address 18-23 | Same as above |
*21 | Quick Arm Enable | 1,0 |
*33 | Alarm (Bell) Timeout | 1 |
*34 | Exit Delay | 60 |
*35 | Entry Delay | 30 |
*37 | Audible Exit Warning | 1,1 |
*39 | Power up previous state | 1 |
*77 | DST Month Start / End | 3,11 |
*78 | DST Weekend Start / End | 2,1 |
*84 | Auto Stay Arm Disable | 0 |
*86 | Alarm Cancel Display | 0 |
*88 | Program Lockout Mode | 0 |
*91 | Option Selection | 8,1 |
*92 | Phone Line Monitoring | 0,0 |
*189 | AUI Enable | 1,1,1,1 |
*197 | Exit Time Display | 1 |
*199 | ECP Fail Display | 0 |
If Monitored | |
*43 | Primary Account Number | Last four digits only |
*44 | Second Account Number | Enter 2nd ACCT # if available |
*48 | Report Format | 7,7 |
*50 | Burglar Dialer Delay | 0 |
*60 | Trouble Report Code | 10 |
*61 | Bypass Report Code | 10 |
*63 | Low Batt Report Code | 10 |
*64 | Test Report Code | 10 |
*67 | RF Trans Low Batt Report Code | 10 |
*68 | Cancel Report Code | 10 |
Continue If Monitored | |
*70 | Alarm Restore Code | 1 |
*71 | Trouble Restore Report Code | 10 |
*74 | Low Batt Restore Report Code | 10 |
*75 | RF Low Batt Restore Report Code | 10 |
*76 | Test Restore Report Code | 10 |
*93 | Reports in Armed Period | 2 |
If Monitored by Phone | |
*41 | Primary Phone Number | Use Primary 800 monitoring center phone # |
*42 | Second Phone Number | Use 2nd monitoring phone number # |
*92 | Phone Line Monitoring | Residential 1,1 / Commercial 1,2 / If Radio Only 0,0 |
*94 | Download Information | phone number for downloader (Add 1 for long distance) |
*95 | Ring Count | #15 |
If Using Radio | |
*29 | Enable IP/GSM | 1,*,* |
*54 | Dynamic Signaling Delay | 0 |
*55 | Dynamic Signaling Priority | 1 |
*91 | Option Selection | 8,2 |
Residential Only | |
*21 | Quick Arm Enable | 1,0 |
*23 | Quick (Forced) Bypass | 1,0 |
Commercial (If Monitored) | |
*62 | AC Restore Report Code | 10 |
*73 | AC Restore Report Code | 10 |
IF YOU WISH TO USE FUNCTION BUTTONS - No response unless monitored |
*56 | Zone Programming | Program Zone 95 as type 09, Zone 96 as Type 08, Zone 99 as Type 06 for commercial (silent response) or 07 for residential (sirens will go off within system) |
*57 | Assign KP Function Buttons | A - Zone 95 (Fire), B - Zone 99 (Police), C - Zone 96 (Medical) |
Exit Programming | |
*99 | Exit Programming, Allowing re-entry with installer code |
Set Clock - Enter Installer Code + #63 + * to move forward, # to move back, 1-pm, 2-pm (always 2 digits) |
Change Master User Code - "Current Code" + 8,0,2 + "New code" + "New Code" |